WhereUpper floor, outdoor unit north side
NotesOutdoor unit icing up overnight; base pan drain suspected.
FlagIce on the outdoor coil in September; drain or refrigerant.
CatalogueServiced every 12 months · expected life 15 years
CatalogueAir filter set · MAC-2390FT · Wash monthly, replace yearly
CatalogueOutdoor fan motor · E12A59300 · On failure
CatalogueKnown to go wrong: Outdoor unit ices up when the base pan drain is blocked